WP3392519 Genuine OEM Whirlpool Dryer Thermal Fuse
The WP3392519 is a genuine Whirlpool OEM thermal fuse mounted on the blower housing next to the blower fan. This fuse is a one-time safety device: as long as the dryer stays within its normal operating temperature, it does nothing at all, but the instant internal temperatures climb high enough — almost always from restricted airflow — the fuse permanently opens the circuit and cuts power to the dryer. That's why a blown thermal fuse produces such a specific symptom: the dryer won't start at all, with no lights, no tumble, and no response, even though the outlet has power.
This fuse opens at approximately 196°F (91°C) and terminates in two 3/16" wire terminals for a direct plug-in fit. Unlike a resettable thermostat, this thermal fuse cannot be reset once it blows — it must be replaced. A blown thermal fuse is almost always a symptom rather than a random failure: restricted exhaust venting is the leading cause, since trapped heat is exactly what the fuse is designed to react to. A shorted heating element or a failed regulating thermostat can also cause the dryer to run hot enough to blow the fuse. It directly replaces 3392519, WP3392519VP, AP6008325, 3388651, 694511, ET401, PS11741460, EAP11741460, AH11741460, EA11741460, PD00002311, G4AP0500, and 80005.
Quick Answer
The WP3392519 Genuine OEM Whirlpool Dryer Thermal Fuse fixes Whirlpool, Maytag, Kenmore, KitchenAid, Roper, Jenn-Air, and Amana dryers that won't start at all — no lights, no tumble, no response to any button. Opens at approximately 196°F (91°C). Two 3/16" wire terminals. Replaces 3392519, WP3392519VP, AP6008325, 3388651, 694511, ET401, PS11741460, EAP11741460, AH11741460, EA11741460, PD00002311, G4AP0500, 80005. Always inspect and clean the dryer venting when replacing this fuse — a blown fuse is a symptom of restricted airflow, and installing a new fuse without fixing the vent will likely blow it again.
Common Problems This Part Fixes
- Dryer won't start at all — no lights, no tumble, no response to any button
- Dryer that stopped working suddenly, especially after running unusually hot
- Dryer runs a short time then shuts off completely and won't restart
- Repeated blown fuses on a dryer with a known venting or airflow restriction
- Clothes coming out extremely hot right before the dryer stopped working
- Dryer that recently smelled like burning or overheating before failing
- Continuity test shows an open circuit across the old fuse
Cross Reference Information
Part numbers can change over a product's lifecycle as manufacturers update designs or release new appliance models. For your convenience, we've included any known superseded, alternate, or cross-reference part numbers that match this item.
Replaces Part Numbers
This dryer thermal fuse directly replaces the following OEM and cross-reference part numbers:
3392519, WP3392519, 3388651, WE4X857, G4AP0500, 6L4101, 6L4101091C, ET401, 3388651, 694511, 80005, AWP47582, PD00002311, EAP11741460, AP6008325, PS11741460
If your part number is not listed above, contact our support team before ordering and we will verify compatibility.
Compatibility
This thermal fuse is compatible with select Whirlpool-built dryers across the Whirlpool family of brands, including:
- Whirlpool electric and gas dryers — WED, WGD series
- Maytag electric and gas dryers — MEDC, MGDC series (select Whirlpool-built models)
- Kenmore dryers (select Whirlpool-built models)
- KitchenAid, Jenn-Air, and Amana dryers (select models)
- Roper, Estate, Inglis, and Crosley dryers (select models)
Verified model numbers include: MEDC465HW0, MGDC465HW0, WED4850HW0, WED4950HW0, WED49STBW1, WET4024HW0, WET4124HW0, WGD4850HW0, WGD4950HW0, YMEDC465HW0, YWED4850HW0, and YWET4024HW0.
Note: This fuse also fits select commercial and stacked washer/dryer combination units on the Whirlpool platform. Always verify your full model number before ordering. Contact our support team with your model number if you're unsure.
Key Features
- Genuine Whirlpool OEM part — factory-specified opening temperature and terminal configuration
- One-time safety device that cuts power if the dryer overheats
- Opens at approximately 196°F (91°C)
- Resolves "won't start at all," "stopped working suddenly," and "clothes came out extremely hot before it died" symptoms caused by a blown fuse
- Two 3/16" wire terminal connectors for a direct plug-in electrical fit
- Mounts to the blower housing next to the blower fan
- Replaces 3392519, WP3392519VP, AP6008325, 3388651, 694511, ET401, PS11741460, EAP11741460, AH11741460, EA11741460, PD00002311, G4AP0500, and 80005
- Compatible with Whirlpool, Maytag, Kenmore, KitchenAid, Roper, Jenn-Air, and Amana dryers
- Genuine OEM replacement — guaranteed fit, materials, and performance
Product Specifications
| Part Number | WP3392519 |
| Part Type | Dryer Thermal Fuse (Thermal Cut-Off) |
| Condition | Genuine OEM |
| Brand | Whirlpool |
| Opening Temperature | Approx. 196°F (91°C) |
| Location | Blower housing, next to the blower fan |
| Terminals | 2 (3/16" wire terminals) |
| Resettable | No — one-time use, must be replaced once blown |
| Dimensions | Approx. 2" x 1/2" |
| Repair Difficulty | Medium — basic disassembly required |
| Quantity | 1 thermal fuse |
| Compatible Brands | Whirlpool, Maytag, Kenmore, KitchenAid, Roper, Jenn-Air, Amana, Estate, Inglis, Crosley |
Installation Notes
Frequently Asked Questions
My dryer has no power at all and the lights won't turn on. Is this the thermal fuse?
It's a strong possibility. When this thermal fuse blows, it cuts power broadly enough that the console lights and control panel can go completely dark, not just the heating function — that's a normal result of how this fuse is wired into the circuit. Before replacing it, confirm the outlet has power and the breaker hasn't tripped, then check the fuse for continuity with a multimeter. If it shows no continuity, this fuse is the correct fix, though it's also worth checking the exhaust ducting since that's the most common underlying cause.
I replaced the fuse and it blew again. What's going on?
This is a strong sign that the underlying cause — almost always restricted airflow — was never addressed. Thermal fuses don't fail from age; they blow because the dryer overheated. If a new fuse keeps blowing, thoroughly inspect and clean the entire exhaust path from the lint trap housing to the outside vent hood, checking for lint buildup, crushed or kinked ductwork, or a vent run that's too long. If airflow checks out and the fuse still blows, have the heating element and cycling thermostat checked as well, since a component stuck in the "on" position can also drive excess heat.
Can I just reset the thermal fuse instead of replacing it?
No. Unlike a cycling thermostat, this thermal fuse is a one-time safety device — once it blows, its internal circuit is permanently broken and it cannot be reset or repaired. Replacement is the only option.
My clothes came out extremely hot right before the dryer died. Is that related?
Yes, this is a classic warning sign. Clothes coming out unusually hot indicates the dryer was already running hotter than normal, which is exactly the condition that leads to a blown thermal fuse. If you noticed this before the dryer stopped working, it strongly points to a ventilation or airflow problem that should be fully addressed before running the dryer again.
Is this an OEM or aftermarket part?
This is a genuine OEM part, manufactured by Whirlpool to factory specifications — guaranteed fit, materials, and performance. It matches the original opening temperature, terminal configuration, and mounting position of the thermal fuse originally installed in your dryer.